Description

Biological Safety Cabinet Class-II Type-A2 designed to protect the Laboratory staff, environment and sensitive work processes in which biological agents are used. The safety cabinet offers a superior level of contamination protection based on two advanced HEPA filters. The Biosafety cabinet configuration is freestanding. The Working area is made of stainless steel 304 grade material. The Cabinet body is made of Galvanized steel with powder coated material. Spillage tray below working surface, stopcock for draining the tray. In order to ensure consistent and reliable down flow velocity across the supply HEPA/ULPA filter over the life of the cabinet, the cabinet use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than just one point across the down flow. The pressure sensor encased in order to protect the sensor from temperature, humidity, and other environmental phenomena that can impact the sensor’s performance. In order to preserve the safety of the user and the environment, the exhaust blower on the cabinet must continue operating when the supply blower stops working. If the exhaust blower  fail, the supply filter will also be turned off. The Cabinet motors automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments.

Features

  • ISO 14644 – 1 and 2 (Class 100) for air cleanliness class limits (air quality) in the working area
  • Incorporate HEPA filter of the class H14 EN 1822
  • Dual DC motorsto control airflow, ensuring a safe environment by maintaining constant downflow and exhaust speeds
  • Heat emissions at 25℃ 0.2 KW
  • Gauges for monitoring the condition of all HEPA filters as well as work space
  • Microprocessor display the inflow and downflow air velocities in real-time on an LED display to ensure the user knows whether or not the cabinet is working under safe operating conditions
  • Front of the cabinet angled 10 ° to help minimize glare on the window to the user and to ensure that the user’s posture is comfortable during a working session.
  • Power Supply: 220-240V, 50Hz AC power supply
  • Dual side wall with negatively pressurized interstitial space.
  • Face velocity of  0.51 m/s
  • Cabinet with lights on and fan at operating speed consume 160 watts for a four foot width and have a reduced energy mode for non-operational maintenance on containment in the work area
  • Microprocessor controller and a large LED display/touch screen display for inflow and downflow air velocity and hours of operation
  • Upgrade with external ducting & virus burnout unit
  • Audible and visual alarms for HEPA filter failure, blower failure, airflow speed failure, and Incorrect window position.
  • All interior and exterior parts painted or smooth to ensure no risk of cuts to users or maintenance personnel
  • Cabinet used for precisely control ventilation to sweep airborne particles produced during routine microbiological procedures away from the user while maintaining a controlled environment for the specimen.
  • Provision for fitting taps for vacuum, water and non-combustible gas
  • Front window 10” sash opening and be made of laminated safety glass to ensure the containment of potentially hazardous samples in the case of accidental glass breakage.
  • In order to provide maximum effectiveness, efficiency and safety to laboratory personnel, UV light programmable to allow for specific exposure times from 0 to 24 hours with separate switch to operate the UV light and automatic shut-off feature present for UV light.
  • Cabinet provided with removable dished work surface with lift out knobs
  • Cabinet automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use
  • Measured in a soundproof room 12’’ in front of the cabinet and 15’’ above the work surface and lower noise levels promote more comfortable and safer working habits for the user.
  • Microprocessor controller which located on a slanted front panel so it is easy to see and reach from a seated working position in front of the cabinet.
  • Two hydraulic height-adjustable stools for working
  • UV light and one set of detachable arms rest and two electrical outlet
  • Incorporate an LED Indicator to indicate filter loading and provide a visual and audible alarm to indicate excessive HEPA filter loading which can result in unsafe airflow deviation.
  • Interior of the front window accessible for cleaning without requiring the user to remove or support the window.
  • Drain pan made of stainless-steel material
  • Fixed  height stand with sturdy castor wheels with locking system
  • Stabilizer cum UPS with one hour back up system
Specs/Model MBMSJ-1018AB-3 MBMSJ-1018AB-4 MBMSJ-1018AB-6
External Size (WxDxH)
1000 X 800 X 1500 mm
1300 X 800 X 1500 mm
1870 X 800 X 1500 mm
Internal Size (WxDxH)
900 X 500 X 800 mm
1200 X 500 X 800 mm
1700 X 500 X 800 mm
Air Flow Volume (Inflow)
350 CFM
350 CFM
350 CFM
Air Flow Volume (Downflow)
225 CFM
225 CFM
225 CFM
Air Flow Volume (Exhaust)
350 CFM
350 CFM
350 CFM
Average Down flow Velocity
55FPM
55FPM
55FPM
Average Inflow Velocity
105FPM
105FPM
105FPM
Airflow Pattern
70% re-circulation, 30% air exhaust
Front sash
5mm clear toughened sliding front door
Supply/Exhaust Filter
HEPA filter efficiency 99.995% for 0.3micron particles
Noise Level
60 dB(A)
Fluorescent light
600Lux
UV lamp
254 nm

Additional Accessories

  • HEPA filter
  • Gas burner  
  • Magnehelic Gauge